PNEUMOSAC®

Made in-bag morcellation easier and simpler with PNEUMOSAC® (SAFETY ISOLATION BAG®) & LIMAS MORCELLATOR®

PNEUMOSAC®

(SAFETY ISOLATION BAG®) Ready to Insert device with NON-TWIST DESIGN & Multiple channels (for in-bag morcellation)

PNEUMSAC® Sizes
  • 1800 ml
  • 2500 ml
  • 3200 ml
  • 4200 ml
  • 5000 ml
Pneumosac
Experts Certify...

SAFETY ISOLATION BAG® (PNEUMOSAC®) Is The best Morcellation Device in the world and made In-Bag Morcellation Simpler.

Media
STEPS OF IN BAG MORCELLATION USING–PNEUMOSAC®
  • Step 1 Once ready for power morcellation, widen the morcellation port incision enough considering the size of the morcellator and the morcellation bag. Slide-out the paper tag from the device as shown on the tag by holding just below the paper tag. Insert the ready to insert PNEUMOSAC® into the abdominal cavity through the incision for morcellation by a clockwise forward pushing into the abdominal cavity to the maximum. Pull out the flexible introducer from the pneumosac by pulling with an anti-clockwise rotation on the introducer. The pneumosac is fully pulled into the abdominal cavity using a non-traumatic grasper such that the black colour layer is facing posterior and blue layer anterior and the Tubular guide facing upward.
  • Step 2 Open the PNEUMOSAC® by Unrolling the Device by pulling the tubular guide while holding on to the mouth of the bag. Make sure that the body of the device is fully opened before trying to place the tumour inside the device. Place the tissue specimens to PNEUMOSAC® be removed inside the and push it to the bottom of the bag.
  • Step 3 Once the specimens are placed inside, - pull out the mouth of the PNEUMOSAC® edge- by- edge till the marking, through the morcellation port using a non- traumatic grasper, keeping the maximum body of the device inside the abdominal cavity. Clamp the mouth of the device with an artery forceps. Then pull out the tubular guide through the primary port either by rail roading or by using a 5 mm telescope. Pull the tubular guide till all the three arrow marks on the tubular guides are brought out.
  • Step 4 Make a small opening to pass the telescope and trocar cannula through the tubular guide. Along with gas flow, advance the telescope first through the tubular guide till it passes through the valve's opening under vision and once the telescope entered the body of the device, then push the trocar fully into the body of the device. Inflate the device with gas. Once the trocar is well entered, tie outside the tubular guide, with one of the thread provided along with the device.
  • Step 5 Once the PNEUMOSAC® is completely filled up, untwist the mouth opening of the device and under vision introduce the LIMAS MORCELLATOR® hand piece through the mouth opening of the PNEUMOSAC®. Put a Tie outside the mouth of the device and the morcellator hand piece with another thread. Once the morcellation is completed and the tissues are extracted, remove the telescope and the morcellator hand piece after untying the threads. Put a tight knot just below the opening made on the tubular guide. and pull out the PNEUMOSAC® through the morcellation port holding at the mouth of the device.
Ordering Information
LIMAS MORCELLATOR® Model: LM 0025
Motor Drive Unit LMD01
Power Cord LMD02
Foot Switch LMD03
Rotor Cable LMD04
Reusable Handle LMD05
Cutter Tubes:
10 mm LMB10.2
12 mm LMB12.2
15 mm LMB15.2
18 mm LMB18.2
Washers:
10 mm LMB10.0
15 mm LMB15.0
18 mm LMB18.0
Handle Head Cap LMHHC.0
Tissue Retrival Endo Bags : 200/300/650/900ml
Videos
Enquiry for Pneumosac®

Our Trusted Clients